-- Type to Search Products --

Carbolite 3-Zone Modular Vertical Tube Furnaces GVC GVC-12-900 1200℃

The tube furnace range GHA (single zone)/GHC (three zone) uses free radiating wire elements embedded within the insulation of the furnace body.The benefit of this design is its flexibility; with the use of tube adapters the same furnace can be used with a variety of tube diameters.

The extended uniform zone in the mid-section of the work tube in the GHC 3-zone furnace is achieved with the use of end zone controllers which track the centre zone temperature and compensate for the loss of heat from the tube ends.

This range of tube furnaces does not include an integral work tube and one must be selected as an additional item.The work tube length is dependent on the application,for example,for use with modified atmosphere or vacuum.The use of a separate work tube has the advantage of protecting the heating elements from damage or contamination.

SKU: GVC-12-900 Categories: , Tag:

Carbolite 3-Zone Modular Vertical Tube Furnaces GVC GVC-12-900 1200℃

Technical Specification

Max. temp. [℃] 1200
Heat-up time [mins] 111
Max. continuous operating temp. [℃]
Dimensions: Usable chamber H x W x D [mm]
Dimensions: External H x W x D [mm] 1860 x 468 x 662
Dimensions: External with door open H x W x D [mm]
Temperature uniformity of ±5℃ within H x W x D [mm]
Volume [litres]
Max. power [W] 5400
Holding power [W] 2281
Thermocouple type N
Furnace Weight [kg] 110
Retort Volume [litres]
Max. temp with Retort
Dimensions External Overall Size
Retort Internal Size
Uniform volume ± 5℃
Uniformi
The tube furnace range GHA (single zone)/GHC (three zone) uses free radiating wire elements embedded within the insulation of the furnace body.The benefit of this design is its flexibility; with the use of tube adapters the same furnace can be used with a variety of tube diameters.

The extended uniform zone in the mid-section of the work tube in the GHC 3-zone furnace is achieved with the use of end zone controllers which track the centre zone temperature and compensate for the loss of heat from the tube ends.

This range of tube furnaces does not include an integral work tube and one must be selected as an additional item.The work tube length is dependent on the application,for example,for use with modified atmosphere or vacuum.The use of a separate work tube has the advantage of protecting the heating elements from damage or contamination.
Standard features

1200℃ maximum operating temperature
Carbolite Gero 301 controller,with single ramp to set-point & process timer
Accepts work tubes with outer diameter up to 170 mm
Heated lengths,single zone 300,450,600,750,900,1050 or 1200 mm (GHA)
Heated lengths,3-zone 450,600,750,900,1050 or 1200 mm (GHC)
End zones 150 mm long on each end (GHC)
Long life,rapid heating,resistance wire elements mounted in rigid,vacuum formed insulation modules
Horizontal configuration mounted on control module
Furnace mounted directly on top of controller base unit


Options (specify these at time of order)

A range of sophisticated digital controllers,multi-segment programmers and data loggers is available. These can be fitted with RS232,RS485 or Ethernet communications
Over-temperature protection (recommended to protect valuable contents & for unattended operation)
A range of additional work tubes,end seals and work tube packages is available for use with modified atmosphere and/or vacuum
Vacuum packages with a choice of rotary vane pump or turbomolecular pump are available for furnaces with tube inner diameters of 60 mm and above
Wide choice of tube diameters and materials is available: eg quartz,ceramic,metal
Insulation plugs & radiation shields to prevent heat loss & improve uniformity
End zones 300 mm long (GHC)
Modified atmosphere and vacuum assemblies are available
Over-temperature protection (recommended to protect valuable contents & for unattended operation)
Retransmission of setpoint control configuration to facilitate programmed cooling
Alternative mounting options are available
Content may be subject to modifications or corrections

Description

Standard features

1200℃ maximum operating temperature
Carbolite Gero 301 controller,with single ramp to set-point & process timer
Accepts work tubes with outer diameter up to 170 mm
Heated lengths,single zone 300,450,600,750,900,1050 or 1200 mm (GHA)
Heated lengths,3-zone 450,600,750,900,1050 or 1200 mm (GHC)
End zones 150 mm long on each end (GHC)
Long life,rapid heating,resistance wire elements mounted in rigid,vacuum formed insulation modules
Horizontal configuration mounted on control module
Furnace mounted directly on top of controller base unit

Options (specify these at time of order)

A range of sophisticated digital controllers,multi-segment programmers and data loggers is available. These can be fitted with RS232,RS485 or Ethernet communications
Over-temperature protection (recommended to protect valuable contents & for unattended operation)
A range of additional work tubes,end seals and work tube packages is available for use with modified atmosphere and/or vacuum
Vacuum packages with a choice of rotary vane pump or turbomolecular pump are available for furnaces with tube inner diameters of 60 mm and above
Wide choice of tube diameters and materials is available: eg quartz,ceramic,metal
Insulation plugs & radiation shields to prevent heat loss & improve uniformity
End zones 300 mm long (GHC)
Modified atmosphere and vacuum assemblies are available
Over-temperature protection (recommended to protect valuable contents & for unattended operation)
Retransmission of setpoint control configuration to facilitate programmed cooling
Alternative mounting options are available
Content may be subject to modifications or corrections

Max. temp. [℃] 1200
Heat-up time [mins] 111
Dimensions: External H x W x D [mm] 1860 x 468 x 662
Max. power [W] 5400
Holding power [W] 2281
Thermocouple type N
Furnace Weight [kg] 110