-- Type to Search Products --

CM Furnaces HIGH TEMPERATURE TUBE, REDUCING ATMOSPHERE, CONTINUOUS TUBE FURNACES TO 400 Series CM-466A-48-1Z 2200℃

The CM 400 Series furnaces are available in a variety of configurations from manually loaded lab-scale units to fully automated production systems. Two basic systems are available. The 400A Series utilize exposed molybdenum grid elements and high alumina insulating brick for temperatures up to 1880℃ (3415℉). The 400Z Series employ exposed tungsten rod elements and zirconia insulating brick for temperatures to 2200℃ (3990℉).

The base model includes inclined doors with protective atmosphere flushes, high heat section, and a cooling section. Depending on application requirements other features are added such as preheat sections, wax or binder removal sections, multiple zone controls, low or high dewpoint features, and turn-key automated pusher systems.

The furnaces are constructed of heavy gauge steel that is welded and reinforced. All power components and controls are located on the main frame assembly. Block graded brick insulation packages are used for high efficiency. The open hearth and exposed element design allows for large tunnel cross-sections and the capability to process extremely heavy loads. When automated the pusher plates (carrier trays) form a train and are pushed through the furnace by an external stoker device. All automation is located outside the heat envelope for ease of maintenance and long life.

Hydrogen, dissociated ammonia, forming gas or any other reducing atmosphere compatible with refractory metal heating elements can be employed. The standard gas panel includes all necessary pressure regulators, flow meters, solenoids and pressure switches for both primary processing atmosphere and standby safety nitrogen. All furnaces come complete with the CM combustion atmosphere safety system. Full details are available on request.

Temperature control is by microprocessor based setpoint controllers operating in conjunction with phase angle-fire SCR power controllers and type CÓ thermocouples. Independent overtemperature instrumentation is standard.

SKU: CM-466A-48-1Z Categories: , Tag:

CM Furnaces HIGH TEMPERATURE TUBE, REDUCING ATMOSPHERE, CONTINUOUS TUBE FURNACES TO 400 Series CM-466A-48-1Z 2200℃

Technical Specification

Dimensions: chamber W x H x D
Dimensions: External with door open H x W [FL]
Dimensions: External W x H x D [mm]
Furnace Weight [lb]
Power Supply Dimension W x H x D
Power Supply Weight
Power Recriutment (Max) KVA
Power Recriutment (Nominal) KVA
Standard Voltage Recriutment
Service Enterance Current Recriutment at 208 volts
Optional Retort Dimension Inside W x H x D
Heatup Rate Minutes
Number of Elements
HEATED LENGTH (in.) 48
HEATED LENGTH (mm) 1219
COOLING LENGTH (in.)
COOLING LENGTH (mm)
NO. OF TUB
The CM 400 Series furnaces are available in a variety of configurations from manually loaded lab-scale units to fully automated production systems. Two basic systems are available. The 400A Series utilize exposed molybdenum grid elements and high alumina insulating brick for temperatures up to 1880℃ (3415℉). The 400Z Series employ exposed tungsten rod elements and zirconia insulating brick for temperatures to 2200℃ (3990℉).

The base model includes inclined doors with protective atmosphere flushes, high heat section, and a cooling section. Depending on application requirements other features are added such as preheat sections, wax or binder removal sections, multiple zone controls, low or high dewpoint features, and turn-key automated pusher systems.

The furnaces are constructed of heavy gauge steel that is welded and reinforced. All power components and controls are located on the main frame assembly. Block graded brick insulation packages are used for high efficiency. The open hearth and exposed element design allows for large tunnel cross-sections and the capability to process extremely heavy loads. When automated the pusher plates (carrier trays) form a train and are pushed through the furnace by an external stoker device. All automation is located outside the heat envelope for ease of maintenance and long life.

Hydrogen, dissociated ammonia, forming gas or any other reducing atmosphere compatible with refractory metal heating elements can be employed. The standard gas panel includes all necessary pressure regulators, flow meters, solenoids and pressure switches for both primary processing atmosphere and standby safety nitrogen. All furnaces come complete with the CM combustion atmosphere safety system. Full details are available on request.

Temperature control is by microprocessor based setpoint controllers operating in conjunction with phase angle-fire SCR power controllers and type CÓ thermocouples. Independent overtemperature instrumentation is standard.
STANDARD SYSTEM INCLUDES:

Total system packaged in common frame including power and control components
Heavy Gauge Welded and Reinforced Steel Frame
Atmosphere Containment Doors with Protective Atmosphere Flushes
Molybdenum Rod Grid Elements (400A), Tungsten Rod Elements (400Z)
Block Graded Brick Insulation Package
Water-Jacketed Cooling Section
Microprocessor Based Set Point Temperature Controller
Phase Angle-Fire SCR Power Controller
Independent Overtemperature Instrumentation
Type CÓ Thermocouples
Manual Operation

USED FOR THESE AND OTHER APPLICATIONS:

Refractory Metals
Powder Metals
Ceramics
Nuclear Fuel
Sintering
Metallizing
Firing
Co-Firing
Annealing
Brazing
Reducing

OPTIONAL FEATURES INCLUDE:

Preheat Sections
Wax and Binder Removal Sections
Multiple Zone Control
Low or High Dewpoint Features
Dewpoint and Oxygen Monitors
Turn-Key Automation with External Stoker
Data Recording Equipment

Description

STANDARD SYSTEM INCLUDES:

Total system packaged in common frame including power and control components
Heavy Gauge Welded and Reinforced Steel Frame
Atmosphere Containment Doors with Protective Atmosphere Flushes
Molybdenum Rod Grid Elements (400A), Tungsten Rod Elements (400Z)
Block Graded Brick Insulation Package
Water-Jacketed Cooling Section
Microprocessor Based Set Point Temperature Controller
Phase Angle-Fire SCR Power Controller
Independent Overtemperature Instrumentation
Type CÓ Thermocouples
Manual Operation

USED FOR THESE AND OTHER APPLICATIONS:

Refractory Metals
Powder Metals
Ceramics
Nuclear Fuel
Sintering
Metallizing
Firing
Co-Firing
Annealing
Brazing
Reducing

OPTIONAL FEATURES INCLUDE:

Preheat Sections
Wax and Binder Removal Sections
Multiple Zone Control
Low or High Dewpoint Features
Dewpoint and Oxygen Monitors
Turn-Key Automation with External Stoker
Data Recording Equipment

HEATED LENGTH (in.) 48
HEATED LENGTH (mm) 1219