-- Type to Search Products --

Lindberg-Blue M 1700℃ Box Furnaces BF51314C 1700℃

Designed for applications which require extremely rapid heat-up rates, with 3500 watt models reaching 1700℃ in as little as 15 minutes, Thermo Scientific™ Lindberg/Blue M™ 1700℃ Box Furnaces with Independent Control are available in two popular chamber sizes, each with a fully programmable independent controller (ordered separately).

SKU: BF51314C Categories: , , Tag:

Lindberg-Blue M 1700℃ Box Furnaces BF51314C 1700℃

Technical Specification

Capacity (Metric) 0.09 cu. ft., 2.5L
Dimensions (D x W x H) Interior 6 x 5 x 5 in. (15.2 x 12.7 x 12.7cm)
Dimensions (H x L x W) Exterior 16 x 16 x 14 in. (40.6 x 40.6 x 35.6cm)
Power Consumption 3500w
Shipping Weight (English) 39kg (85 lb.)
Temperature Control Independent (CC59256PC0MC)
Temperature Range (Metric) 1700℃
Type Multiprogram, Multisegment
Electrical Requirements 208/240V 50/60Hz
Amperage
Item Description
Certifications/Compliance
Temperature Uniformity
Temperature Stability
Shelves
Includes
For Use With (Application)
Insulation
Diameter Process Tube
Display
Heated Zone
Accuracy
Analysis Time
Ports
Sample Size
Length (Metric) Exterior
Designed for applications which require extremely rapid heat-up rates, with 3500 watt models reaching 1700℃ in as little as 15 minutes, Thermo Scientific™ Lindberg/Blue M™ 1700℃ Box Furnaces with Independent Control are available in two popular chamber sizes, each with a fully programmable independent controller (ordered separately).
Features

Available in two popular chamber sizes
Double shell design for lower external cabinet temperature with energy savings
Moldatherm™ high temperature ceramic fibre insulation with advanced graded design for fast heat-up and resistance to thermal shock
Vertically hinged door lifts up and out of the way to save space and minimize exposure to the operator
Removable panels for easy access to replaceable heating elements and thermocouples
Moldatherm hearthplate supports load and protects chamber from spills or mishandling
High volume cooling fans move air between inner and outer chamber to reduce exterior shell temperatures and improve
Smart Heating Elements
Molybdenum disilicide elements with unique right angle bend and sidewall mounting reduce maintenance usually associated with element termination and mounting
Designed for easy replacement without matching resistance values
Fast heat-up and recovery with excellent uniformity and energy efficiency
Increased resistance to thermal shock, ideal for rapid cycling over extended periods
1700℃ Controller, Programmable, with Communications
Provide multiple programs and multiple segments for ramp (up and down) and dwell (timed hold) temperature control
Visually displays ramp rate, dwell time, program segment and percent power out-put
Holdback feature allows the operator to set a−process vs setpoint temperature value which, when exceeded, holds the program to allow the process to catch up
Includes a selectable self-tuning feature which sets the best PID settings for the thermal process
LED display indicates actual temperature (high limit overtemperature protection is standard)
Control console includes a circuit breaker, power module, transformer and cooling fans
Controllers include RS485 data port(communications card and port) for connection to remote computer, allowing modification, interrogation and data transfer of all instrument control and configuration parameter. Up to 30 units can be connected to one PC. Software is not included but is available as an option.
Option B Overtemperature Control (OTC)
Adjustable digital overtemperature control, factory installed on selected control consoles with−B suffix designation
Protects furnace and load in the event of primary control circuit failure
Overrides main controller and shuts off power to furnace if high limit is reached
Manual re-set required for safety
Operates via signal from independent thermocouple

Description

Features

Available in two popular chamber sizes
Double shell design for lower external cabinet temperature with energy savings
Moldatherm™ high temperature ceramic fibre insulation with advanced graded design for fast heat-up and resistance to thermal shock
Vertically hinged door lifts up and out of the way to save space and minimize exposure to the operator
Removable panels for easy access to replaceable heating elements and thermocouples
Moldatherm hearthplate supports load and protects chamber from spills or mishandling
High volume cooling fans move air between inner and outer chamber to reduce exterior shell temperatures and improve
Smart Heating Elements
Molybdenum disilicide elements with unique right angle bend and sidewall mounting reduce maintenance usually associated with element termination and mounting
Designed for easy replacement without matching resistance values
Fast heat-up and recovery with excellent uniformity and energy efficiency
Increased resistance to thermal shock, ideal for rapid cycling over extended periods
1700℃ Controller, Programmable, with Communications
Provide multiple programs and multiple segments for ramp (up and down) and dwell (timed hold) temperature control
Visually displays ramp rate, dwell time, program segment and percent power out-put
Holdback feature allows the operator to set a−process vs setpoint temperature value which, when exceeded, holds the program to allow the process to catch up
Includes a selectable self-tuning feature which sets the best PID settings for the thermal process
LED display indicates actual temperature (high limit overtemperature protection is standard)
Control console includes a circuit breaker, power module, transformer and cooling fans
Controllers include RS485 data port(communications card and port) for connection to remote computer, allowing modification, interrogation and data transfer of all instrument control and configuration parameter. Up to 30 units can be connected to one PC. Software is not included but is available as an option.
Option B Overtemperature Control (OTC)
Adjustable digital overtemperature control, factory installed on selected control consoles with−B suffix designation
Protects furnace and load in the event of primary control circuit failure
Overrides main controller and shuts off power to furnace if high limit is reached
Manual re-set required for safety
Operates via signal from independent thermocouple

Capacity (Metric) 0.09 cu. ft., 2.5L
Dimensions (D x W x H) Interior 6 x 5 x 5 in. (15.2 x 12.7 x 12.7cm)
Dimensions (H x L x W) Exterior 16 x 16 x 14 in. (40.6 x 40.6 x 35.6cm)
Power Consumption 3500w
Shipping Weight (English) 39kg (85 lb.)
Temperature Control Independent (CC59256PC0MC)
Temperature Range (Metric) 1700℃
Type Multiprogram, Multisegment
Electrical Requirements 208/240V 50/60Hz