-- Type to Search Products --

Lindberg-Blue M LGO Box Furnaces BF51842C 100℃ to 1200℃

Utilize the latest technical advances in heating elements, insulation and temperature control integrated into a self-contained cabinet with Thermo Scientific™ Lindberg/Blue M™ LGO Box Furnaces. Furnaces feature proprietary LGO (light gauge overbend) heating elements and Thermo Scientific™ Moldatherm™ insulation for efficient and economical transfer of heat to chamber, with low exterior temperatures. Variable heat-up rate eliminates thermal shock to materials with inherently quick heat up and cool down rates.

$90,000.00

SKU: BF51842C Categories: , Tags: ,

Lindberg-Blue M LGO Box Furnaces BF51842C 100℃ to 1200℃

Technical Specification

Capacity (Metric) 2.0 cu.ft., 55.3L
Dimensions (D x W x H) Interior 15 x 15 x 15 in. (38.1 x 38.1 x 38.1cm)
Dimensions (H x L x W) Exterior 28 x 29 x 33 in. (71.1 x 73.7 x 83.8cm)
Power Consumption 5800w
Shipping Weight (English) 127kg
Temperature Control Digital Mutli Seg/1 Prog
Temperature Range (Metric) 100℃ to 1200℃
Type Multisegment Single program
Electrical Requirements 208/240V 50/60Hz
Amperage
Item Description
Certifications/Compliance
Temperature Uniformity
Temperature Stability
Shelves
Includes
For Use With (Application)
Insulation
Diameter Process Tube
Display
Heated Zone
Accuracy
Analysis Time
Ports
Sample Size
Length (Metric) Exterior
Utilize the latest technical advances in heating elements, insulation and temperature control integrated into a self-contained cabinet with Thermo Scientific™ Lindberg/Blue M™ LGO Box Furnaces. Furnaces feature proprietary LGO (light gauge overbend) heating elements and Thermo Scientific™ Moldatherm™ insulation for efficient and economical transfer of heat to chamber, with low exterior temperatures. Variable heat-up rate eliminates thermal shock to materials with inherently quick heat up and cool down rates.
Key Features Choice of side hinge or vertical lift door Air vent (1 in. dia., top) and air inlet (0.375 in. dia., rear) for inert atmosphere exchange (may experience some leakage at door) Self-tuning, digital instrumentation for precise temperature setpoint and display Platinel II™ thermocouple for long-term stability 0.6 cu. ft. models feature vertical lift door; 2 cu. ft. models feature horizontal side swing door, hot side facing away from operator for protection Microprocessor Control Microprocessor-based self-tuning PID control (proportional, integral, derivative) provides optimum thermal process, prevents overshoot Control panel designed for easy access and maintenance Main power ON/OFF switch on control panel Adjustable high-limit overtemperature protection Simultaneous LED display of actual temperature vs. setpoint Can be configured to display temperature in either℃ or ℉ Safety door switch interrupts power to heating element when door is opened; protects heating elements and minimizes exposure to end-user Removable shelves for versatility Moldatherm™ hearthplate supports load and prevents damage due to spillage Digital, Single-Setpoint Controller Single segment, single setpoint, one ramp to setpoint Digital Single-Program, Multiple-Segment Programmable Controller Single program with multiple segments for ramp (up and down) and dwell (timed hold) temperature control Digital Multiple-Program, Multiple-Segment Programmable Controller Available on models with (P) suffix designation Multiple programs and segments for ramp (up and down) and dwell (timed hold) temperature control Overtemperature Control (OTC) Adjustable digital overtemperature control, available on selected models with(B)suffix designation Protects furnace and load in the event of primary control circuit failure Overrides main controller and shuts off power to furnace if high limit is reached Manual reset required for safety Operates via magnetic contacts through signal from independent thermocouple Flowmeter Option (FM) (Inert Atmosphere Only) Available on selected models with (FM) designation Gas flowmeter, adjustable, located on front control panel Adjustable flowrate, range 1.0 to 100 cu. ft./hr. standard Suitable for inert gas or airflow to chamber Allows fresh air exchange for ashing applications Not suitable for combustible or volatile gases Ordering Information: Required power cord and hardwiring not included. Optional RS485 Digital Communications Port allows controller to be connected to a PC for remote monitoring and control of the furnace; up to 30 units can be connected to one PC. Specify Option B for Overtemperature Control (OTC) when ordering. Includes One two-part shelf (0.6 cu. ft. models have one shelf position at center position; 2.0 cu. ft. models have three shelf positions)

Description

Key Features

Choice of side hinge or vertical lift door
Air vent (1 in. dia., top) and air inlet (0.375 in. dia., rear) for inert atmosphere exchange (may experience some leakage at door)
Self-tuning, digital instrumentation for precise temperature setpoint and display
Platinel II™ thermocouple for long-term stability
0.6 cu. ft. models feature vertical lift door; 2 cu. ft. models feature horizontal side swing door, hot side facing away from operator for protection
Microprocessor Control

Microprocessor-based self-tuning PID control (proportional, integral, derivative) provides optimum thermal process, prevents overshoot
Control panel designed for easy access and maintenance
Main power ON/OFF switch on control panel
Adjustable high-limit overtemperature protection
Simultaneous LED display of actual temperature vs. setpoint
Can be configured to display temperature in either℃ or ℉
Safety door switch interrupts power to heating element when door is opened; protects heating elements and minimizes exposure to end-user
Removable shelves for versatility
Moldatherm™ hearthplate supports load and prevents damage due to spillage
Digital, Single-Setpoint Controller

Single segment, single setpoint, one ramp to setpoint
Digital Single-Program, Multiple-Segment Programmable Controller

Single program with multiple segments for ramp (up and down) and dwell (timed hold) temperature control
Digital Multiple-Program, Multiple-Segment Programmable Controller

Available on models with (P) suffix designation
Multiple programs and segments for ramp (up and down) and dwell (timed hold) temperature control
Overtemperature Control (OTC)

Adjustable digital overtemperature control, available on selected models with(B)suffix designation
Protects furnace and load in the event of primary control circuit failure
Overrides main controller and shuts off power to furnace if high limit is reached
Manual reset required for safety
Operates via magnetic contacts through signal from independent thermocouple
Flowmeter Option (FM) (Inert Atmosphere Only)

Available on selected models with (FM) designation
Gas flowmeter, adjustable, located on front control panel
Adjustable flowrate, range 1.0 to 100 cu. ft./hr. standard
Suitable for inert gas or airflow to chamber
Allows fresh air exchange for ashing applications Not suitable for combustible or volatile gases
Ordering Information:

Required power cord and hardwiring not included. Optional RS485 Digital Communications Port allows controller to be connected to a PC for remote monitoring and control of the furnace; up to 30 units can be connected to one PC.
Specify Option
B for Overtemperature Control (OTC) when ordering.
Includes
One two-part shelf (0.6 cu. ft. models have one shelf position at center position; 2.0 cu. ft. models have three shelf positions)

Capacity (Metric) 2.0 cu.ft., 55.3L
Dimensions (D x W x H) Interior 15 x 15 x 15 in. (38.1 x 38.1 x 38.1cm)
Dimensions (H x L x W) Exterior 28 x 29 x 33 in. (71.1 x 73.7 x 83.8cm)
Power Consumption 5800w
Shipping Weight (English) 127kg
Temperature Control Digital Mutli Seg/1 Prog
Temperature Range (Metric) 100℃ to 1200℃
Type Multisegment Single program
Electrical Requirements 208/240V 50/60Hz